TECHNICAL ASSOCIATES products

GAMMA ELECTRONIC PERSONAL DOSIMETER
Model NRY20001

* Radiation Detected: Gamma: 50KeV to 6MeV.
* Energy Response: µ25%, 60KeV - 3MeV (Ref: Cs137).
* Display Range: Total Dose: 1.00 to 99,999 mRem.
* Integrated Dose Accuracy: µ10% (1 to 99,999mRem/hr).
* Dose Rate Accuracy: µ10% (20 to 99,999mRem/hr).
* Alarms:
    Visual Display: Flashing display value indicates reading in excess of set alarm values.
    Audio 1: 75dB. Continuous tone for Dose Amount
    Audio 2: 75dB. Chirp tone for Dose Rate
* PC Set Up: Communication with personal computer allows setting of dosimeter control number, integrated dose, dose rate, calibration constant or alarm set points.
*Calibration Constant: 60-140% (in 1% steps).
* Power Supply: 1-AAA alkaline battery, 500 hours continuous, On/Off power Switch.
* Operating Environment:
    Temperature: 0-45°C.
    Humidity: 95% RH or less (non-condensing)
    Drop Protection: 1.5m (5ft.).
    EMI/RFI rejection from Cell Phones: >5cm distance.
* Dimensions: 2.2'' x 4'' x 0.6'' (55mm x 103mm x 15mm)
* Weight: 110grams (4 oz.).


MOVING FILTER ALPHA PLUS BETA-GAMMA AIR MONITOR SYSTEM
Model SAAM-4HVM

* AIRBORNE ALPHA and BETA-GAMMA PARTICULATES
* COUNTS SEPARATELY AND SIMULTANEOUSLY
* RUGGED, 100% DUTY CYCLE
* HIGH THROUGHPUT
* OPERATES 2-6 WEEKS UNATTENDED
* PRINTED RECORD
* BCD AND SERIAL PULSE OUTPUT
* 3'' LEAD SHIELDING
* 4 CHANNEL AIR MONITOR:
    CHANNEL 1: SHORT LIFE ALPHA
    CHANNEL 2: LONG LIFE ALPHA
    CHANNEL 3: SHORT LIFE BETA
    CHANNEL 4: LONG LIFE BETA

TLC SCANNER – Model HY-3
ACCEPTS PAPER CHROMATOGRAMS, TLC PLATES, AND ELECTROPHORESES
SCANS UP TO SIX TRACES SIMULTANEOUSLY
THREE DETECTOR TYPES FOR ANY NUCLIDE
    BETAS: H-3, C-14, P-32, etc...
    GAMMAS: Fe-55, I-125, Tc-99m, etc...
HIGH PRECISION AT ALL SPEEDS DUE TO DIGITAL DRIVE
WILL DETECT LOWER LEVELS THAN ANY PREVIOUS SCANNER
ULTRA-SENSITIVE - WILL DETECT: 80 picoCi of H-3
                       3 picoCi of C-14
                              1.5 picoCi of P-32
                       1.5 picoCi of I-131
SPARTIAL RESOLUTION: 1MM
LARGE 10'' X 20'' TABLE
COMPLETELY AUTOMATIC
GM or GAS FLOW or SCINTILLATION DETECTORS
QUANTITATIVE - EASY INTEGRATION OF AREA UNDER PEAK
MAY BE INTERFACED TO COMPUTER OR COMPUTING INTEGRATOR

PORTABLE RADON MONITOR  (Type: Ion Chamber)
Model TBM-IC-RN
* DIGITAL READOUT: 6 Digits Rate, 8 Digits Integrate
* SMALL LIGHTWEIGHT 26 oz.
* TBM PACKAGE
* FLAT RESPONSE - FREE AIR ION CHAMBER
* SEES AXIALLY BELOW 5 KEV GAMMA OR X-RAY
* SEES ALPHA, BETA, GAMMA, X-RAY
* FAST RESPONSE
* WIDE RANGE
other models: FR-32, FR-42, PTG-7RN, SSS-12-M3, SSS-59
See: http://www.tech-associates.com/dept/sales/radonpicker.html